TQ402 111-402-000-013 A1-B1-C050-D000-E050-F0-G000-H05 proximity transducer
TQ402 111-402-000-013 A1-B1-C050-D000-E050-F0-G000-H05 proximity transducer
Brand:
UngroupedItem NO.:
TQ402 111-402-000-013 A1-B1-C050-D000-E050-F0-G000-H05Order(MOQ):
1 PCPayment:
T/TProduct Origin:
SwitzerlandShipping Port:
XIAMENWarranty:
1 YearDescription:
The TQ402 111-402-000-013 A1-B1-C050-D000-E050-F0-G000-H05 is a non-contact proximity transducer designed for measuring the relative displacement of rotating machine shafts. It uses the eddy-current principle to detect changes in the gap between the probe tip and a metallic target, allowing shaft movement to be measured without physical contact.
This specific configuration uses a 50 mm body length with an M10 × 1 mounting thread and a 5 m integral coaxial cable. The D000 option specifies zero unthreaded length, while F0 and G000 indicate that no additional flexible-hose protection is included. With H05, the complete measurement chain is configured for a 5 m total system length.
When connected to a compatible signal conditioner, the transducer forms part of a calibrated proximity measurement system for monitoring shaft relative vibration, axial position and other displacement-related conditions on rotating machinery. The system supports a frequency response from DC to 20 kHz (-3 dB).
Application Value
Measures Shaft Movement Without Mechanical Contact
Because the sensing element does not physically touch the rotating shaft, the transducer can continuously measure the gap between the probe tip and the metallic target. This is particularly useful for high-speed machinery where a contact-type sensor would introduce mechanical loading or wear.
Provides Direct Displacement Information for Machinery Monitoring
The measurement is based on the actual distance between the probe and the shaft surface. This makes the system suitable for detecting relative shaft vibration and axial movement, providing displacement information that can be used by machinery protection and condition-monitoring systems.
FAQ
1.What does E050 mean in the complete part number?
E050 specifies a nominal 5.0 m integral cable, with the datasheet allowing a ±500 mm cable-length tolerance.
2. What do B1 and C050 specify?
B1 specifies an M10 × 1 body thread, while C050 specifies a 50 mm body length. D000 indicates a 0 mm unthreaded length.
3.What is the frequency response of the TQ402 measurement system?
The specified system frequency response is DC to 20 kHz (-3 dB). The actual measurement range and sensitivity depend on the selected signal-conditioner configuration.
Ordering Information:
TQ 402 111-402-000-013 proximity transducer